  1. .TOPIC:
  2. Contents
  3. Square Feet            Cooking            Electric Heat  
  4. Small Appliance        Heating            Continuous 
  5. Laundry                Cooling            Four or More  
  6.  
  7. Fixed Appliance        Motor Loads        Service Info       
  8. Customer Info          Note               Service REQ#       
  9.  
  10. Reports                Data Base          Help on Help      
  11. Command Buttons        Service Schedule   Formulas  
  12.  
  13. Demand Calculation  Special Keys  Maximum Field Length 
  14.  
  15. Database Repair Utility         Database Packing Utility     
  16.  
  17. .TOPIC:
  18. Special Keys
  19.  
  20. * F1 Help       -  Displays a help message about the
  21.                    task you are performing.
  22.  
  23. * F2 Search     -  Displays a list box to find records. Press
  24.                    the first letter of the name to jump to
  25.                    that location.
  26.  
  27. * ENTER or TAB  -  Signal the computer to accept an entry
  28.                    that you have made, and move the cursor
  29.                    to the next field.
  30.  
  31. * SHIFT + TAB   -  Accept this entry and move the cursor 
  32.                    back to the previous field.
  33.  
  34. * ALT + HOT KEY -  Used to select a menu item or command 
  35.                    button function.
  36.  
  37. * ESC           -  Cancel the task you are performing and
  38.                    exits the program. 
  39.                    
  40. * Up Arrow      -  Accept this entry and move the cursor 
  41.                    to the previous field.
  42.  
  43. * Down Arrow    -  Accept this entry and move the cursor 
  44.                    to the next field.
  45.  
  46. * Page Up       -  When at the customer name, page up will 
  47.                    move to the previous record. 
  48.  
  49. * Page Down     -  When at the customer name, page down will 
  50.                    move to the next record. 
  51.  
  52. * Home          -  Move the cursor to the beginning of the 
  53.                    current field.
  54.  
  55. * End           -  Move the cursor to the end of the 
  56.                    current field.
  57.  
  58. .TOPIC:
  59. Demand Calculation
  60.  
  61. The Single Dwelling Demand Calculation evaluates the 
  62. loads of a new or existing single dwelling. Calculate 
  63. the required service size in accordance with ARTICLE 220 - 
  64. BRANCH-CIRCUIT AND FEEDER CALCULATIONS. Produce Reports  
  65. for the general and optional methods. Complies with NFPA 70 
  66. National Electrical Code 1993 edition.
  67.  
  68. PRINT SINGLE DWELLING FORM: 
  69. ~~~~~~~~~~~~~~~~~~~~~~~~~~~
  70. Print a form that can be used IN THE FIELD to collect the 
  71. information for the demand calculation.
  72.  
  73. .TOPIC:
  74. Square feet
  75.  
  76. Enter the square feet of floor area from the outside 
  77. dimensions of the building. The computed floor area 
  78. shall not include open porches, garages, or unused 
  79. or unfinished spaces not adaptable for future use. 
  80.  
  81. Enter the living space.
  82.  
  83. REF: 220-3(b), 220-11, tables 220-3(b), 220-11
  84.  
  85. .TOPIC:
  86. Small appliance
  87.  
  88. Enter the quantity of 20 ampere, two wire, 
  89. small appliance branch circuits.
  90.  
  91. REF: 220-4(b), 220-16(a), 220-11, table 220-11
  92.  
  93. .TOPIC:
  94. Laundry
  95.  
  96. Enter the quantity of 20 ampere, two wire, 
  97. laundry branch circuits.
  98.  
  99. REF: 220-4(c), 220-16(b), 220-11, table 220-11
  100.  
  101. .TOPIC:
  102. Heating
  103.  
  104. Enter the total wattage of the heating system. 
  105.  
  106. In the case of a heat pump, if supplementary heat is not on
  107. at the same time as the heat pump the smaller load need not 
  108. be added to the total.
  109.  
  110. Electric Heat  Continuous  Four or More   
  111.  
  112. .TOPIC:
  113. Electric Heat
  114.  
  115. Pressing the space bar will place an X inside the box. 
  116. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  117.  
  118. If the heat is electric put an X in the box 
  119.  
  120. This is used for the Optional Calculation Method to 
  121. determine if the heating load can be calculated at 65 
  122. percent of the nameplate rating(s) of electric space heating, 
  123. if less then four separately controlled units.
  124.  
  125.  
  126.  
  127. Continuous  Four or More 
  128.  
  129. .TOPIC:
  130. Continuous
  131.  
  132. Pressing the space bar will place an X inside the box. 
  133. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  134. If the heat is electric and the usual load is expected 
  135. to be continuous at the full nameplate value put an X
  136. in the box. 
  137.  
  138. If the heating is not continuous, however, it is a heat 
  139. pump with the compressor load larger than the Supplemental 
  140. load put an X in the box.   
  141.  
  142. REF: Table 220-30(1)
  143.    
  144. Electric Heat  Four or More  
  145.    
  146. DEFINITION OF CONTINUOUS = A load where the maximum current 
  147.                            is expected to continue for three 
  148.                            hours or more.   REF: Article 100
  149.  
  150. .TOPIC:
  151. Four or More
  152.  
  153. Pressing the space bar will place an X inside the box. 
  154. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  155.  
  156. If the heat is electric and is four or more separately 
  157. controlled units put an X in the box. 
  158.  
  159.  
  160. This information is used for the Optional Calculation 
  161. Method to determine if the Heating load can be 
  162. calculated at 40 percent of the nameplate rating(s) of 
  163. electric space heating for four or more separately 
  164. controlled units. 
  165.  
  166. REF: 220-30.
  167.  
  168. Electric Heat  Continuous     
  169.  
  170. .TOPIC:
  171. Cooling
  172.  
  173. Enter the total wattage of the cooling system. This value 
  174. will also be compared against the Motor loads of the fixed 
  175. appliance schedule to determine 25% of the largest motor.
  176.  
  177. REF: 220-21
  178.  
  179. .TOPIC:
  180. Dryer
  181.  
  182. Enter the wattage of the electric dryer. For the general 
  183. method if an electric dryer is present the minimum demand
  184. load is 5000 watts. for the optional method the dryer is 
  185. calculated at nameplate.
  186.  
  187. REF: 220-18
  188.  
  189. .TOPIC:
  190. Cooking
  191.  
  192. Enter up to three electric ranges or cooking appliances. The
  193. minimum wattage is 1751 to a maximum of 12,000. The program 
  194. will automatically classify each category according to column 
  195. A,B or C and apply the demand factors accordingly.  In addition 
  196. when calculating two or three units the result will be compared 
  197. against column A to give the lowest allowable demand.
  198.  
  199.  
  200. REF: 220-19
  201.  
  202. .TOPIC:
  203. Motor Loads
  204.  
  205. Enter the name, volts and amps for the Fixed appliance that 
  206. are motor loads, such as well pump, compactor, vent fan, 
  207. disposal, pool motor, etc. This group will be compared with 
  208. each other as well as the Cooling load to determine 25% of 
  209. the largest motor.
  210.  
  211. REF: 220-17, 430-24, 430-25, 430-26
  212.  
  213.         Table 430-148 Full-Load Currents in Amperes
  214.           Single-Phase Alternating-Current Motors
  215.   ════════════════════════════════════════════════════════
  216.    HP         115v         200v         208v         230v
  217.   ────────────────────────────────────────────────────────  
  218.     1/6        4.4          2.5          2.4          2.2
  219.     1/4        5.8          3.3          3.2          2.9
  220.     1/3        7.2          4.1          4.0          3.6
  221.     1/2        9.8          5.6          5.4          4.9
  222.     3/4       13.8          7.9          7.6          6.9
  223.   ──────────────────────────────────────────────────────── 
  224.    1          16            9.2          8.8          8
  225.    1½         20           11.5         11           10
  226.    2          24           13.8         13.2         12
  227.    3          34           19.6         18.7         17
  228.   ──────────────────────────────────────────────────────── 
  229.    5          56           32.2         30.8         28
  230.    7½         80           46           44           40
  231.   10         100           57.5         55           50
  232.   ════════════════════════════════════════════════════════
  233.  
  234. .TOPIC:
  235. Fixed appliance
  236.  
  237. Enter the fastened in place fixed appliances that are 
  238. wattage loads, such as water heater, dishwasher, etc.
  239.  
  240. REF: 220-17, 430-24, 430-25, 430-26
  241.  
  242. .TOPIC:
  243. Customer Info
  244.  
  245. Enter information about the customer.
  246.  
  247. The Name, City, State & Zip fields are indexed fields. 
  248. The records will be displayed in alphabetical order 
  249. based on the indexed field. 
  250.  
  251. The name field is the default index field. 
  252.  
  253. When at the customer name, Page Up will move to the 
  254. previous record. Page Down will move to the next 
  255. record. 
  256.  
  257. Special Keys  Help on Help  Data Base  
  258.  
  259. .TOPIC:
  260. Note
  261. This field will hold information up to 72 characters and
  262. will print directly below the customer block. 
  263.  
  264.  
  265. Frank & Mary Connoly
  266. 33 Peace Road
  267. Hudson, NH 12345
  268.  
  269. Courtesy of ABC Electrical contractor 1-234-567-8901 
  270.  
  271. .TOPIC:
  272. Service REQ#
  273.  
  274. This is the number that is issued from the local utility
  275. company to reference a specific service or project.
  276.  
  277. .TOPIC:
  278. Service Info
  279. Examples of use:
  280.  
  281. Panel...... Square D 200 amp 40 circuit surface main breaker
  282. Conductors. 4/0 AL conductor type XHHW in 2" PVC
  283. Grounding.. One 5/8" X 8' rod in cellar under panel #4 cu 
  284.  
  285. Report 1... 155' run from pole 24-17 along driveway
  286. Report 2... Granite State Electric Utility Co.  603-898-9798
  287. Report 3... 15 spare circuits as of 3/12/93
  288. Report 4... Lot #14
  289. Report 5...
  290. Report 6... Ran spare 2" PVC in trench for future fiber 
  291. Report 7... Optics cable as per owners request
  292.  
  293. This will print on the reports when the long report 
  294. is selected.
  295.  
  296. .TOPIC:
  297. Reports
  298. Produce reports for: 
  299.  
  300. 1. The general or optional method for a new service 
  301. 2. The optional method for an existing service  
  302. 3. Long reports have the service information attached
  303. 4. Short reports have the calculation only
  304.  
  305. Reports can go to: 
  306. 1. Disk via an ASCII file that you can edit 
  307. 2. Go to printer port LPT1 thru LPT3
  308.  
  309. Report notes:
  310. 1. When sending a report to a file you may replace an existing
  311.    file or append to an existing file.
  312. 2. When sending a report to the printer 1 to 10 copies can
  313.    be printed at a time.
  314.  
  315. .TOPIC:
  316. Data base
  317.  
  318. All records can be saved to disk in a data base file named
  319. DEMAND.MDB. The data base will first show records on an 
  320. ascending order based on the name field first.
  321.  
  322. Name   =   Name   ->  city  ->  state 
  323. City   =   City   ->  name  ->  state
  324. State  =   State  ->  name  ->  city
  325. Zip    =   Zip    ->  name  ->  city
  326.  
  327. Example: The name index will sort based on the name field
  328.          first, then as a sub-index it will sort on city 
  329.          and lastly on state.
  330.  
  331. .TOPIC:
  332. Help on help
  333.  
  334. Selecting a Help link:
  335. ----------------------
  336. With a mouse - click on phrases outlined by two triangles.
  337. With the keyboard - Press TAB or Shift-TAB to select a link.
  338. Press ENTER to jump to that topic.
  339.  
  340. Scrolling the Help window:
  341. --------------------------
  342. With a mouse      - click on the horizontal or vertical 
  343.                     scroll bars.
  344.  
  345. With the keyboard - press the cursor navigation keys.
  346.  
  347. Closing the Help window:
  348. ------------------------
  349. With a mouse - double click on the window's control box icon.
  350.                top left.
  351.  
  352. With the keyboard - press Esc or Ctrl-F4.
  353.  
  354. Contents - displays a table of contents for the application's
  355.            Help. Press C to select Contents.
  356.  
  357. Search   - opens a dialogue box that lists all available Help
  358.            topics. Select a topic from the list box and press 
  359.            ENTER. Press S to select Search.
  360.  
  361. Back     - jumps to the last Help topic viewed. Press B to 
  362.            select Back.
  363.  
  364. History  - lists the last 20 Help topics viewed. Jump to a
  365.            topic by selecting from the list box and pressing 
  366.            ENTER. Press T to select History.
  367.  
  368. Copy     - Copies the contents of the current Help topic into
  369.            an edit area.  Select the text you want copied to 
  370.            the Clipboard and choose Copy.  Choosing Copy 
  371.            without selecting any text in the edit area copies 
  372.            the entire Help topic to the Clipboard. Press P to 
  373.            select Copy.
  374.  
  375. .TOPIC:
  376. Command buttons
  377. New rec....... Create a new record.
  378.  
  379. Update........ Update the current record. When a record 
  380.                is changed in any way, a prompt to update
  381.                will be requested.
  382.  
  383. Delete........ Delete the current record.
  384.  
  385. Prev.......... Move to the previous record in the indexing 
  386.                sequence.
  387.  
  388. Next.......... Move to the next record in the indexing 
  389.                sequence.
  390.  
  391. Find.......... Find a specific record. The search will take 
  392.                place on the field that is the current index.
  393.  
  394. Calc.......... Bring up a pop up calculator.
  395.  
  396. Info.......... Toggle the service information screen.
  397.  
  398. Exit.......... Exit the program.
  399.  
  400. Esc........... The Esc button will move out of the program.
  401.  
  402. .TOPIC:
  403. Database Packing utility
  404.  
  405. ISAMPACK purges records marked for deletion and recovers disk
  406. space formerly used by deleted records in 32K blocks.
  407.  
  408. If you have deleted records from the data file the space that
  409. the record used is still a part of the file.  
  410.  
  411. Syntax     ISAMPACK  DEMAND.MDB
  412.  
  413. Database Repair Utility   
  414.  
  415. .TOPIC:
  416. Database Repair Utility
  417.  
  418.  
  419. ISAMREPR recovers databases that become corrupted; it 
  420. recreates them by systematically evaluating every table 
  421. and index and using every piece of internally consistent
  422. information in the file.
  423.  
  424. Syntax     ISAMREPR  DEMAND.MDB
  425.  
  426. Database Packing Utility   
  427.  
  428. .TOPIC:
  429. Service schedule
  430.                 Conductor Types and Sizes
  431.           RH-RHH-RHW-THHW-THW-THWN-THHN-XHHW-USE  
  432.  ─────────────────────────────────────────────────────────
  433.                        Aluminum or 
  434.   Copper              Copper-Clad AL        Rating in Amps
  435.  ─────────────────────────────────────────────────────────
  436.    AWG                     AWG
  437.     4                       2                    100
  438.     3                       1                    110
  439.     2                     1/0                    125
  440.     1                     2/0                    150
  441.   1/0                     3/0                    175
  442.   2/0                     4/0                    200
  443.   3/0                     250 kcmil              225
  444.   4/0                     300 kcmil              250
  445.   250 kcmil               350 kcmil              300
  446.   350 kcmil               500 kcmil              350
  447.   400 kcmil               600 kcmil              400
  448.  ─────────────────────────────────────────────────────────
  449.  
  450. .TOPIC:  
  451. Formulas
  452.  
  453.      OHM'S LAW
  454.      ~~~~~~~~~
  455.      Watts   =   E  x I    =   Volts  X  Amps
  456.      Watts   =   E² ÷ R    =   (Volts squared) ÷ Ohm's
  457.      Watts   =   I² x R    =   (Amps squared) X  Ohm's
  458.      ───────────────────────────────────────────────────
  459.      Volts   =   I X R     =   Amps X  Ohm's
  460.      Volts   =   P ÷ I     =   Watts   ÷  Amps
  461.      Volts   =   √(PxR)    =   Square of (Watts X Ohm's)
  462.      ───────────────────────────────────────────────────
  463.      Amps    =   P ÷ E     =   Watts   ÷  Volts
  464.      Amps    =   E ÷ R     =   Volts   ÷  Ohm's
  465.      Amps    =   √(P ÷ R)  =   Square of (Watts ÷ Ohm's)
  466.      ───────────────────────────────────────────────────
  467.      Ohm's   =   E ÷ I     =   Volts ÷  Amps     
  468.      Ohm's   =   E² ÷ P    =   (Volts squared) ÷ Watts     
  469.      Ohm's   =   P ÷ I²    =   Watts ÷  (Amps squared)     
  470.      ───────────────────────────────────────────────────
  471.  
  472. .TOPIC:
  473. Maximum field length
  474.  
  475. The Maximum Field Lengths for the various fields is the data
  476. that will be saved in the data base record. If you type in a 
  477. longer field it will not be saved in the data base file.
  478.  
  479. Customer Name ..... 24
  480. Customer Address... 24
  481. Customer City ..... 24
  482. Customer State .... 24
  483. Customer Zip ...... 24
  484. Customer Note1 .... 70
  485. Customer Note2 .... 70
  486. Service Request ... 16
  487. Fixed Name ........ 24